Display screen compared to other products, the biggest advantage is the color is more accurate, but due to certain factors, the display will appear the phenomenon of color is not normal. Typically there will be three kinds of display color is not normal forms:
1, the display color obvious abnormalities;
2, the color of the display subjective special preference;
3, the graphics card or graphics card driver failure, and software compatibility problems.
Solve Step one: When the display is a color cast, we should first check the connection part of the liquid crystal display, such as D-Sub, DVI, or other data signal line and the display interface or an interface card is securely attached, because most of the screen bias color problems are caused by loose connections or poor contact caused.Coding
System lcd module We suggest that you connect the signal on the transmission line screws.
Solve Step Two: If it is not the connection problem, we recommend everyone in the system menu of the "Color" option, see "warm", "normal", "cool", "user-defined" This four common options to see whether we choose not to correct color options. For most ordinary users, use the default "normal" mode is sufficient. If the change is more complex, the user can select the system menu "Restore Defaults (restore factory settings)" option, restore the factory settings to the monitor.
Solve Step Three: If the first two parts are completely normal, we conducted the third step of checking: Check whether the video card or driver issue. This process is also very simple: the host computer is connected to a normal display, or connect the monitor to another normal host, to see if it still will be cast. If the issue is resolved, indicating that the host computer graphics card or driver's fault; if not resolved, indicating a liquid crystal display their own problems.
If the fault monitor itself, TFT LCD
Displays so basically belongs to the internal circuitry chip failure problems, then we suggest that you should be sent to monitor the official brand service center for repair detection.
Access to information mainly through display and interactive interface with the electronic technology and electronics integrated rapid development of LCD modules in the smart instrumentation to achieve a mix of graphics and text display, man-machine dialogue to achieve the on-screen menu operation thus graphic LCD module with its small size, low power consumption, the development cycle is short, safe, reliable, flexible, etc., in the smart meter has been more widely used.